Api.ReadLogData method
The method is defined in remote interface and is used to read logged data from runtime machine.
Namespace: IntervalZero.KINGSTAR.OpcUa.Api
Assembly: IntervalZero.KINGSTAR.OpcUa.Api (in IntervalZero.KINGSTAR.OpcUa.Client.dll) Version: 4.4.0.0
Syntax
public KsReturn<LogData> ReadLogData(
int ChannelCount,
int StartIndex,
int EndIndex
)
Public Function ReadLogData(
ByVal ChannelCount As Integer,
ByVal StartIndex As Integer,
ByVal EndIndex As Integer
) As KsReturn(Of Integer)
Parameters
ChannelCount
Type: int
Number of channels to read.
StartIndex
Type: int
Index of the first data to collect.
EndIndex
Type: int
Index of the last data to collect.
Return value
Returns Type: KsError and an unsigned short integer value.
Remarks
The ReadLogData can only read at most 50000 points in one call, so EndIndex – StartIndex <= 49999. If your logged data is greater than the limitation, you need to use the method several times to retrieve the data.
Usable EtherCAT states
ecatOffline, ecatInit, ecatBoot, ecatPreOP, ecatSafeOP, ecatOP
Examples
N/A